APC Back UPS 200 Manuel d'utilisateur Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
APC Corporate
132 Fairgrounds Road
West Kingston, RI 02892
USA
Tel: (401)789-0204
Fax: (401)789-3710
APC Europe
Ballybrit Industrial Estate
Galway, Ireland
Tel: (+353) 91 702000
Fax: (+353) 91 755275
APC Asia/Pacific
Level 27 Northpoint
100 Miller Street
North Sydney, NSW 2060, Australia
Tel: (+612) 9955-9366
Fax: (+612) 9955-2844
© 1998 APC. All Rights Reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners.
Specifications are subject to change without notice. * See policy for details on Lifetime Equipment Protection.
APC’s quality
system is
certified by
ISO 9002
standards.
PowerFax™: (800)347-FAXX
APC Web site: www.apcc.com
For more information call:
Tel: (800)800-4APC - US & Canada
Tel: (401)789-0204 - Worldwide
Software and Accessories
PowerChute
®
plus
PowerNet
®
UPS Accessories
Workstations
Back-UPS
®
Back-UPS
Office®
Back-UPS Pro
®
Servers
Smart-UPS
®
Datacenters
Matrix-UPS
®
Symmetra
®
Peripherals
SurgeArrest
®
ProtectNet
®
PowerManager
996-0036C
SPECIFICATIONS Back-UPS 200 Back-UPS 300 Back-UPS 500 Back-UPS 650
INPUT
Capacity 200VA(130W) 300VA(180W) 500VA(330W) 600VA(400W)
Input voltage window for utility >103 Vac
operation (adjustable)
Nominal input 120 Vac single phase, 60 Hz ± 5%
OUTPUT
Voltage (on battery) Stepped approximation to sine wave output at 115 Vac ± 5%
Overload protection On battery-internal current limiting, On line circuit breaker
Frequency (on battery) 60 Hz ± 5%
Transfer time 8ms 8ms 4ms 4ms
SURGE PROTECTION AND FILTERING
Surge energy rating, peak current capability 240 Joules, 6500A
Normal mode clamping response time 0 ns, instantaneous
Normal mode surge voltage let through when <5% of test peak voltage
subjected to IEEE 587 Cat. A 6kVA test
Normal mode noise suppression Full time EMI/RFI filtering
Fax/Modem protection N/A N/A Single line (2-wire, RJ11)
ENVIRONMENTAL
Ambient operation 10,000ft. (3,000 meters) max. elevation, 0-95% humidity
non-condensing, 32-104 deg. F (0-40 deg. C)
Audible noise <40 dBA (3' from surface)
On line/on battery 8/200 10/230 20/275 25/430
thermal dissipation (BTU/hr)
PHYSICAL
Input line 6ft. line input cord, NEMA 5-15 Plug
Total # of UPS Receptacles 2 battery + surge 2 battery + surge 2 battery + surge, 3 battery + surge
1 surge only 3 surge only
Maximum dimensions 6.0x3.4x13.1" 6.6x4.7x14.2"
(151x86x333mm) (168x119x361mm)
Net weight 13.1lb(5.9kg) 13.1lb(5.9kg) 15.4lb(7.0kg) 23.0lb(10.4kg)
Shipping weight 15.8lb(7.2kg) 15.8lb(7.2kg) 18.0lb(8.2kg) 26.5lb(12.0kg)
USER REPLACEABLE BATTERIES
Type Hot swappable, sealed, maintenance-free lead acid
Typical recharge time to 90% of full capacity 5-10 hours, depending upon model
Management Manual self-test, adjustable battery transfer points and alarm settings
SYSTEM WARNING DIAGNOSTICS
Visual warnings UPS on, site wiring fault
Audible alarms On battery, low battery, UPS overload
COMMUNICATIONS INTERFACE
DB-9 connector Serial interface port can be connected to workstations or PCs for automatic datasaving and unattended shutdown.
(FREE mail-in offer for PowerChute plus software with APC Back-UPS500 and APC Back-UPS650.)
CONFORMANCE
Approvals UL, CSA, FCC, Novell
Warranty 2 year comprehensive, including battery
Equipment Protection Policy $25,000 lifetime protection, including lightning (see policy for details)
TYPICAL RUNTIME IN MINUTES (for most recent sizing information go to sizing.apcc.com)
SYSTEM Watts Back-UPS 200 Back-UPS 300 Back-UPS 500 Back-UPS 650
Desktop/Mini Tower Pentium with 14" or 15" Monitor 110 6 14 19 40
Desktop/Mini Tower Pentium II / Pentium Pro with 14" or 15" Monitor 130 5 10 14 31
Tower Pentium with 17" Monitor 150 - 8 11 25
Desktop/Mini Tower Pentium with 21” Monitor 170 - 6 8 20
Desktop/Mini Tower Pentium II / Pentium Pro with 21" Monitor 190 - - 7 14
Tower Pentium II / Pentium Pro with 21" Monitor 210 - - 6 11