Smart-UPS®Models 600XL,900XL and 2000XLUser'sUser'sUser'sUser'sUser'sManualManualManualManualManualTM
Page 83.0 Presentation3.1 600VA and 900VA models - 120 Vac versionNote: Use only factory supplied or authorized Battery packs.Rear viewFront viewBatte
Page 93.0 Presentation3.2 600VA and 900VA models - 220/230/240 Vac versionNote: Use only factory supplied or authorized Battery packs.Front view Rear
Page 103.0 Presentation3.3 2000VA model - 120 Vac versionNote: 2000VA model Battery pack not shown. Use only factory supplied or authorizedBattery pa
Page 113.0 Presentation3.4 2000VA model - 120 Vac version optionsThe -1, -2 and -4 wiring device options for the 120 Vac version 2000VA model UPS ares
Page 12Front view3.0 Presentation3.5 2000VA model - 220/230/240 Vac versionNote: 2000VA model Battery pack not shown. Use only factory supplied or au
Page 134.0 Installation4.1 Receiving inspectionOnce the UPS has been removed from its shipping container, it should be inspected fordamage that may ha
Page 144.0 Installation4.4 Connect battery packFollow the instructions listed below to install and lock the battery pack coupler.Note: Use only factor
Page 154.0 Installation4.4 Connect battery pack - continuedNote: The number of 2000VA model Battery packs that may be connected is limited onlyby the
Page 164.0 Installation4.5 Connect UPS to service and enable - continued 220/230/240 Vac versionsThe 600VA and 900VA UPS is not furnished with an inp
Page 174.0 Installation4.6 Plug loads into UPSPlug all loads to be protected into the UPS. Do not exceed the UPS's capacity as given insection 9
Important safety instructions!Please read this manual!Veuillez lire ce manuel!Bitte lesen Sie dieses Anleitungshandbuch!¡Se ruega leer este manual de
Page 185.0 Operation5.1 Display features5.1.1 On / Test / Alarm disable pushbuttonThe On / Test / Alarm disable pushbutton is used to control activati
Page 195.0 Operation5.2 Battery capacity bar graphThe battery capacity bar graph continuously displays the state of battery charge. In theabove examp
Page 205.0 Operation5.4 Line voltage bar graphThe line voltage bar graph displays the UPS's input voltage in discrete steps. Line voltageis disp
Page 215.0 OperationNote: Option switches maybe thrown at any time andtake effect immediately.5.5.3 Replace batteryIn the event the UPS's battery
Page 225.0 Operation5.6 Option switches - continued5.6.2 Option switch 2Option switch 2 controls different functions depending upon the UPS version ty
Page 235.0 Operation5.7 Extended capabilitiesThe following sections briefly describe the UPS’s extended capabilities. These advancedfunctions are acc
Page 245.0 Operation5.7 Extended capabilities - continued● Output voltage, internal temperature, battery voltage, battery capacity - The UPScontinuous
Page 255.0 Operation5.7 Extended capabilities - continuedoutput voltage may be set to a nominal 220, 225, 230 or 240 Vac. The UPS’s default settingis
Page 266.0 UPS Monitoring6.1 OverviewA UPS system alone provides excellent protection from brief power problems. However,during an extended power out
Page 276.0 UPS Monitoring6.4 Computer interface portThe computer interface port is diagramed below for your reference. Those with technicalabilities
Page 1Table of contents1.0 Introduction ... 22.0 Safety!...
Page 287.0 DifficultyCaution ! CAUTION ! This Uninterruptible Power Source contains potentially hazardous voltages. Do notattempt to disassemble
Page 29FRANÇAIS7.0 DifficultéAttention ! ATTENTION! Cette source d’alimentation permanente (UPS) contient des circuits haute tensionprésentant un
Page 30DEUTSCH7.0 SchwierigkeitVorsicht ! VORSICHT! Im Inneren dieser unterbrechungsfreien Stromversorgung herrschen potentiellgefährliche Spannun
Page 31ESPAÑOL7.0 Dificultad¡Cuidado! ¡CUIDADO! Esta Fuente de energía ininterrumpible contiene niveles de voltaje peligrosos enpotencia. No inte
Page 327.0 Difficulty7.1 Troubleshooting chartPROBLEM POSSIBLE CAUSE ACTION TO TAKEUPS will not turn on.1. UPS Enable switch is in the offposition or
Page 337.0 Difficulty7.2 Battery replacement checkYou can expect to receive 3 to 6 years of service life from the UPS's Battery packs wheninstall
Page 347.0 Difficulty7.3 Obtaining ServiceThe troubleshooting chart in section 7.1 covers most of the difficulties that a user mayencounter under cond
Page 358.0 Storing the UPS8.1 Storage conditionsThe UPS should be covered and stored upright in a cool dry location. The UPS should bestored with its
Page 369.0 SpecificationsNote: Where specifications ratings differ, values for the 220/230/240 Vac versions are givenin [ ] brackets.9.1 InputNominal
Page 379.0 Specifications9.4 Noise and surge suppressionSurge energy rating (one time, 10/1000 µs waveform): 480 J.Surge current capability (one time
Page 21.0 Introduction1.1 OverviewThis equipment is a high performance line interactive uninterruptible power source(UPS) designed to provide clean, r
Page 38Note: Typical run time values given in bold type are for the 900VA model only. Run times are typical at 25°C (77°F).9.9 Typical recharge time
Page 399.9 Typical recharge time and run time versus load9.9.2 2000VA modelsNumber Of1 2 3 4 5 6 7 8 9 1010 plusadder * recharge to 90% of capacityBat
Page 40DECLARATION OF CONFORMITYApplication of Council Directive(s): 89/336/EECStandard(s) to which Conformity is Declared: EN55022, EN50082-1Manu
Limited WarrantyAmerican Power Conversion (APC) warrants its products to be free from defects in materialsand workmanship for a period of two years fr
990-7004-A-2 10/93( PHONE PHONE PHONE PHONE PHONE(+33) 1.64.62.59.00 in Eur(+33) 1.64.62.59.00 in Eur(+33) 1.64.62.59.00 in Eur(+33) 1.64.62.59.00 in
Page 31.0 Introduction1.2 SmartBoostSmartBoost allows continuous on-line operation during extended brownouts or low linevoltage conditions. The UPS c
Page 42.0 Safety !Caution! CAUTION ! To reduce the risk of electric shock, disconnect the Uninterruptible Power Source fromthe mains before instal
Page 52.0 Sécurité !Attention! ATTENTION! Pour réduire le risque d’électrocution, débranchez la prise principale de la sourced’alimentation perman
Page 62.0 Sicherheit !Vorsicht! VORSICHT! Um die Gefahr eines elektrischen Schlages auf ein Minimum zu reduzieren, dieunterbrechungsfreie Stromvers
Page 7ESPAÑOL2.0 ¡ Seguridad !¡Atencion! ¡ATENCION! Para reducir el riesgo de descarga eléctrica, desconecte de la red la Fuente de energíaininter