APC RAID Subsystem SCSI-SATA II Spécifications Page 84

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 94
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 83
Falcon II SCSI-SATA Installation and Hardware Reference Manual
B.3 Drive Tray Specifications
Specifications
Height 28mm
Width 110mm
Depth 218.92mm
Key-lock Yes
B.4 Power Supply Specifications
Specifications
Nominal Power 460W with active PFC
12.0V: 32A (Max.)
DC Output 5.0V: 32A (Max.)
3.3V: 30A (Max.)
Input Frequency 47 ~ 63Hz
Input Voltage 100VAC @ 10A – 240VAC @ 5A with PFC
Power Factor
Correction
Hold-up Time
Yes
At least 16ms at 115/230VAC full load after a loss
of AC input
I
2
C
Through backplane to controller
Over-temperature
Protection
Lost cooling or excessive ambient temperature
Cooling Fans Two fans for each unit (inside PSU)
Operating: 0°C to 50°C (32°F to 122°F)
Temperature
Humidity
Altitude
Storage: -40°C to 70°C (-40°F to 158°F)
Operating: 20% ~ 90% non-condensing
Non-operating: 5% ~ 95% non-condensing
Operating: 0 - 10,000 ft
Non-operating: 0 - 40,000 ft
Acoustic Noise
115V input, full load of
+5V; 0.5A of +12V
50 dB max.
B-4
Drive Tray Specifications
Vue de la page 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 93 94

Commentaires sur ces manuels