1User Guide Silcon DP300E Series 480V 400-500kVA
7OA0004 US rev. 02
Copyright © 1999 APC Denmark A/S
Due to continuous product development information
given in this manual is subject to change without notice.
7OA0004 US rev. 02
Silcon DP300E Series
480V 400–500kVA
User Guide
Vue de la page 0
1 2 3 4 5 6 ... 37 38

Résumé du contenu

Page 1 - User Guide

1User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Copyright © 1999 APC Denmark A/SDue to continuous product development informationgiv

Page 2 - SAVE THESE INSTRUCTIONS

10 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02WARNING!If the UPS is out of service formore than 48 hours theconnected batteries

Page 3 - Table of Contents:

11User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 0210. Turn all input switches (Q001) to position “0“.On systems with dual utility, tu

Page 4 - Introduction

12 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02DP300EDP300EQ010aQ001aQ002aQ004Q010bQ001b Q002bUtility 1Q003Service bypass switchH

Page 5 - CAUTION!

13User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02The following can be carried out on any UPS14. Press on the keyboard15. Press or

Page 6

14 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02DP300EDP300EQ010aQ001aQ002aQ004Q010bQ001b Q002bUtility 1Q003Service bypass switchH

Page 7

15User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Operation3.0 OperationThe display is used to show parameters, alarms/messages, and

Page 8

16 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 024.0 Programming Parameters4.1 GeneralSome operating parameters can be programmed d

Page 9

17User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming Parameters4.2.2 Keys used for programming4.2.3 Programming example - sw

Page 10 - 7OA0004 US rev. 02

18 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 024.3 Programming of system configuration parametersThe system configuration paramet

Page 11

19User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming Parameters4.3.2 Programming example – change charge voltage to 446V*Act

Page 12

2 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important

Page 13

20 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 024.4 Programming of battery monitorAction Display shows1. Press and simultaneous

Page 14

21User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming Parameters4.5 Parallel programming/operationProgramming parameters for

Page 15 - Operation

22 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming ParametersAction Display shows1. Press and simultaneously to openfor

Page 16 - Programming Parameters

23User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Parallel operation alarms.General.If alarms concerning the parallel operation commu

Page 17

24 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Measurements98.01.1610.22,13Mains 1 voltage480 480 480 VacBattery current+ 20 AdcM

Page 18 - Programming parameters

25User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Alarms6.0 Alarms - What To Do6.1 GeneralAlarms are indicated by the red LED (above

Page 19

26 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Alarms6.4 The events loggerThe events logger is a memory stack, in which the last

Page 20

27User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Alarms6.6 Possible alarmsPossible alarm1. Peak current limiter active2. Bypass powe

Page 21

28 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02AlarmsPossible alarmDescription Action20. High temp. isolationtransformer21. High

Page 22

29User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02AlarmsPossible alarm Description Action39. System is locked in oper.mode40 RAM1 mem

Page 23

3User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Table of Contents:1.0 Introduction1.1 General1.2 The display unit2.0 Stop, Start &am

Page 24 - Measurements

30 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 027.0 Remote Display7.1 Remote Display OperationThe remote display is an inactive un

Page 25 - 6.0 Alarms - What To Do

31User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Remote DisplayPossible alarm DescriptionBattery MCB is off Battery MCCB not closed

Page 26 - 6.4 The events logger

32 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 028.0 Preventive Maintenance8.1 GeneralThe maintenance of the Silcon DP300E UPS syst

Page 27 - 6.6 Possible alarms

33User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02WARNING!The UPS must at least be inoperation for min. 16 hours in a3 month period t

Page 28

34 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Preventive Maintenance8.5 Battery monitor testThe battery monitor has two main pu

Page 29

35User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Preventive Maintenance8.5.4 Operation of the battery monitorThe operation of the ba

Page 30 - Remote Display

36 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02NOTE:When using economy modethere is NO power factorcorrection on the input orregu

Page 31

37User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 0210.0 System Specifications10.1 Technical dataInput Voltage 3 x 480VVoltage toleranc

Page 32 - Preventive Maintenance

38 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 0211.0 How to Contact APCHow to Contact APCFor more information call:Tel: (800) 800-

Page 33

4 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Introduction1.0 Introduction1.1 GeneralCongratulations on your choice of Silcon DP3

Page 34

5User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Stop, Start & Operating the External Service Bypass Panel2.0 Stop – Start and Op

Page 35

6 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 021. Prepare the system by opening the front door(s).2. Continue with the next point

Page 36 - Economy Operation

7User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Start up of system now completed.2.5 Start (from complete power down)2.5.1 Starting

Page 37 - System Specifications

8 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Single UtilityDual Utility2.6 Operating the external service bypass switch, single

Page 38 - How to Contact APC

9User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Action1. Turn the input switch (Q001) to position “1”.If dual utility is present, tu