APC RAID Subsystem SCSI-SATA II Informations techniques Page 175

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 259
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 174
Appendix
A-3
A.3 RAID 1
RAID 1 is commonly referred to as disk mirroring as all data is duplicated on two or more disks. This provides a high
access rate and very high data availability. RAID 1 has low performance for write operations but very high performance
for intensive read operations.
RAID 1: Mirroring
Characteristics
Storage capacity = the capacity of the smallest disk
A minimum of two disks are required.
Fault tolerance: Very good
Read transaction rate: Good. Better than a single drive but worse than many other RAID levels.
Write transaction rate: Worse than a single drive, but better than many other RAID levels
100% data redundancy means that in the event of disk failure, data can be copied directly to the
replacement without rebuilding.
All the disks contain the same data.
Recommended use
Accounting
Payroll
Finance
Any application requiring high availability
A
A
B
C
D
A
B
C
D
CONTROLLER
B
C
G
F
D
E
=
Figure A-2 RAID 1 disk array
Vue de la page 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 258 259

Commentaires sur ces manuels

Pas de commentaire